HAL will be down for maintenance from Friday, June 10 at 4pm through Monday, June 13 at 9am. More information
Skip to Main content Skip to Navigation
Journal articles

Imaging and quality assessment of high-harmonic focal spots

Abstract : We present a direct method of studying the focusability of an intense, short-pulse extreme-ultraviolet (XUV) beam obtained by high-harmonic generation. We perform near-field imaging of the focal spot of five high-harmonic orders strongly focused by a broadband toroidal mirror. To visualize the focal spot directly, we image the fluorescence induced by an XUV beam on a cerium-doped YAG crystal on a visible CCD camera. We can thus measure the harmonic spot size on a single image, together with the Strehl ratio, to evaluate the quality of focusing. Such techniques should become instrumental in optimizing the focusing conditions and reaching intensities required for exploring attosecond nonlinear optics in the XUV range.
Document type :
Journal articles
Complete list of metadata

https://hal-polytechnique.archives-ouvertes.fr/hal-00522992
Contributor : Thuy Le Connect in order to contact the contributor
Submitted on : Monday, October 4, 2010 - 10:46:17 AM
Last modification on : Wednesday, May 11, 2022 - 3:22:03 PM

Identifiers

Collections

Citation

C. Valentin, D. Douillet, S. Kazamias, Thierry Lefrou, G. Grillon, et al.. Imaging and quality assessment of high-harmonic focal spots. Optics Letters, Optical Society of America - OSA Publishing, 2003, 28 (12), pp.1049-1051. ⟨10.1364/OL.28.001049⟩. ⟨hal-00522992⟩

Share

Metrics

Record views

114